{"id":3496,"date":"2023-06-09T12:22:45","date_gmt":"2023-06-09T12:22:45","guid":{"rendered":"https:\/\/raynexmedical.com\/x-ray\/?post_type=product&#038;p=3496"},"modified":"2023-07-04T07:13:19","modified_gmt":"2023-07-04T07:13:19","slug":"canontoshiba-e7242-series-xray-tube","status":"publish","type":"product","link":"https:\/\/nikki.health\/x-ray\/product\/canontoshiba-e7242-series-xray-tube\/","title":{"rendered":"Canon\/Toshiba E7242 series X-Ray Tube"},"content":{"rendered":"<ul>\n<li>Rotating anode X-ray tube assembly for the purpose of general diagnostic X-ray procedures.<\/li>\n<\/ul>\n<ul>\n<li>Specially processed Rhenium-tungsten faced molybdenum target of 74 mm diameter.<\/li>\n<\/ul>\n<ul>\n<li>These tubes have foci 1.5 and 0.6, and are available for a maximum tube voltage 125 kV.<\/li>\n<\/ul>\n<ul>\n<li>Accommodated with IEC60526 type high-voltage cable receptacles.<\/li>\n<\/ul>\n<h2>General Data:<\/h2>\n<p><strong>IEC Classification (IEC60601-1:2005):<\/strong>\u00a0Class \u2160 ME EQUIPMET<\/p>\n<h2>Electrical:<\/h2>\n<p><strong>Circuit:<br \/>\n<\/strong>High Voltage Generator: Constant Potential High-Voltage Generator<br \/>\nGrounding: Center-grounded<\/p>\n<p><strong>Nominal X-ray Tube Voltage (IEC60613:2010):<br \/>\n<\/strong>Radiographic: 125 kV<\/p>\n<p><strong>Nominal Focal Spot Value (IEC60336:2005):<br \/>\n<\/strong>Large Focus: 1.5<br \/>\nSmall Focus: 0.6<\/p>\n<p><strong>Nominal Anode Input Power (at 0.1s):<\/strong><\/p>\n<div class=\"responsivetable\">\n<table border=\"1\" width=\"358\">\n<tbody>\n<tr>\n<td><\/td>\n<td>50 Hz<\/td>\n<td>60 Hz<\/td>\n<\/tr>\n<tr>\n<td>Large Focus:<\/td>\n<td>47 Kw<\/td>\n<td>50 kW<\/td>\n<\/tr>\n<tr>\n<td>Small Focus:<\/td>\n<td>16.5 kW<\/td>\n<td>18 kW<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>&nbsp;<\/p>\n<p><strong>Nominal Radiographic Anode Input Power (IEC60613:2010):<\/strong><\/p>\n<div class=\"responsivetable\">\n<table border=\"1\" width=\"358\">\n<tbody>\n<tr>\n<td><\/td>\n<td>50 Hz<\/td>\n<td>60 Hz<\/td>\n<\/tr>\n<tr>\n<td>Large Focus:<\/td>\n<td>37 Kw<\/td>\n<td>41 kW<\/td>\n<\/tr>\n<tr>\n<td>Small Focus:<\/td>\n<td>14 kW<\/td>\n<td>16 kW<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>&nbsp;<\/p>\n<h2>Motor Ratings:<\/h2>\n<div class=\"responsivetable\">\n<table border=\"1\" width=\"358\">\n<tbody>\n<tr>\n<td>Stator: XS-RA<\/td>\n<td colspan=\"2\">Starting<\/td>\n<td>Running<\/td>\n<\/tr>\n<tr>\n<td>Driven Frequency \u00a0 [Hz]<\/td>\n<td colspan=\"2\">50\/60<\/td>\n<td>50\/60<\/td>\n<\/tr>\n<tr>\n<td>Input Power\u00a0 [W]<\/td>\n<td>1050<\/td>\n<td>270<\/td>\n<td>43<\/td>\n<\/tr>\n<tr>\n<td>Voltage\u00a0<sup>1) 3)<\/sup>\u00a0\u00a0 [V]<\/td>\n<td>200<\/td>\n<td>100<\/td>\n<td>40<\/td>\n<\/tr>\n<tr>\n<td>Current\u00a0<sup>2)<\/sup>\u00a0 [A]<\/td>\n<td>6.0<\/td>\n<td>3.0<\/td>\n<td>1.2<\/td>\n<\/tr>\n<tr>\n<td>Min. Speed Up\u00a0<sup>4)<\/sup>\u00a0 [s]<\/td>\n<td>0.8<\/td>\n<td>1.5<\/td>\n<td>\u2013<\/td>\n<\/tr>\n<tr>\n<td>Capacitor\u00a0 [\u03bcF]<\/td>\n<td>24<\/td>\n<td>24<\/td>\n<td>24<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p><strong>Note:<\/strong><\/p>\n<ol>\n<li>Applied voltage between common and main terminal.<\/li>\n<li>Common current.<\/li>\n<li>The every applied voltage must be never exceeded 110% of the above specification.<\/li>\n<li>The speed-up time is allowed up to 110% of the above specification.<\/li>\n<\/ol>\n<p><strong>Anode Speed:<br \/>\n<\/strong>50 Hz: Minimum 2700 min-1<br \/>\n60 Hz: Minimum 3200 min-1<\/p>\n<p><strong>Stator Resistance:<\/strong><br \/>\nCommon-Main Winding:\u00a0 27.5 \u2126<br \/>\nCommon-Auxiliary Winding: 58.0 \u2126<\/p>\n<p><strong>Resistance between Housing and Low Voltage Terminals:<\/strong>\u00a0Minimum 2 M\u2126<\/p>\n<p><strong>Normal Operating Range of the Housing Temperature:<\/strong>\u00a016 ~ 75 \u00b0C<\/p>\n<p><strong>Mode of Operation:<\/strong>\u00a0Intermittent<\/p>\n<h2>Mechanical:<\/h2>\n<p><strong>Dimensions:<\/strong>\u00a0See dimensional outline<br \/>\nOverall Length: 479 mm<br \/>\nMaximum Diameter: 152.4 mm<\/p>\n<p><strong>Target:<br \/>\n<\/strong>Anode Angle: 14 degrees<br \/>\nDiameter: 74 mm<br \/>\nConstruction:\u00a0 Rhenium-Tungsten faced molybdenum<\/p>\n<p><strong>Filtration:<br \/>\n<\/strong>Permanent Filtration: 0.9 mm Al \/ 75 kV IEC60522:1999<br \/>\nAvailable Additional Filter combination (0.4 \u2013 1.5 mm): Maximum 2.4 mm Al \/ 75 kV<\/p>\n<p><strong>Radiation Protection (In accordance with IEC60601-1-3:2008):<br \/>\n<\/strong>Leakage Technique Factor: 125 kV, 4 mA<\/p>\n<p><strong>X-ray Coverage:<\/strong>\u00a0354 \u00d7 354 mm at SID 710 mm<\/p>\n<p><strong>Weight (Approx.):<\/strong>\u00a016 kg<\/p>\n<p><strong>High Voltage Receptacle:<\/strong>\u00a0To meet the requirements of IEC60526 Corrigendum1:2010<\/p>\n<p><strong>Cooling Method:<\/strong>\u00a0Natural or forced air<\/p>\n<p><strong>Tube Housing Model Number:<\/strong><br \/>\nE7242X:\u00a0 XH-121<br \/>\nE7242FX:\u00a0 XH-126<br \/>\nE7242GX: XH-150<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Rotating anode X-ray tube assembly for the purpose of general diagnostic X-ray procedures. Specially processed Rhenium-tungsten faced molybdenum target of 74 mm diameter. These tubes have foci 1.5 and 0.6, and are available for a maximum tube voltage 125 kV. Accommodated with IEC60526 type high-voltage cable receptacles. General Data: IEC&hellip;<\/p>\n","protected":false},"featured_media":3495,"template":"","meta":{"om_disable_all_campaigns":false},"product_cat":[76],"product_tag":[],"class_list":["post-3496","product","type-product","status-publish","has-post-thumbnail","hentry","product_cat-x-ray-components"],"_links":{"self":[{"href":"https:\/\/nikki.health\/x-ray\/wp-json\/wp\/v2\/product\/3496","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/nikki.health\/x-ray\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/nikki.health\/x-ray\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/nikki.health\/x-ray\/wp-json\/wp\/v2\/media\/3495"}],"wp:attachment":[{"href":"https:\/\/nikki.health\/x-ray\/wp-json\/wp\/v2\/media?parent=3496"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/nikki.health\/x-ray\/wp-json\/wp\/v2\/product_cat?post=3496"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/nikki.health\/x-ray\/wp-json\/wp\/v2\/product_tag?post=3496"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}